Megates Energy manufactures metal-enclosed modular MV switchgear for 12 kV, 24 kV and 36 kV distribution systems, including incoming/outgoing feeders, transformer protection, metering, circuit-breaker, load-break-switch, bus-coupler and cable-connection functions. Review ME36 switchgear types, technical data and quotation requirements.

Megates Energy metal-enclosed modular switchgear provides configurable medium voltage switchgear for utility, industrial and project-based distribution requirements. The ME36 family covers 12 kV, 24 kV and 36 kV MV switchgear applications and is also described in international specifications as metal enclosed switchgear or modular MV panels.
Manufactured in accordance with TS EN 62271-200, the switchgear can be configured for load-break-switch incoming/outgoing feeders, fused transformer protection, circuit-breaker protection and feeder panels, metering panels, bus-coupler panels and cable-connection functions.
Thanks to its compact modular structure, this medium-voltage switchgear can be used in industrial facilities, organized industrial zones, commercial buildings and concrete transformer kiosk applications. You can also review switchgear components for circuit-breaker, load-break-switch, metering and protection equipment required by the project.
| Rated Voltage | 12 kV / 24 kV / 36 kV |
| Rated Current | 630 A — 2000 A |
| Short‑Circuit Current | 16 kA / 25 kA |
| Impulse Voltage | 75 kV / 95 kV / 170 kV |
| Protection Class | IP 67 (Internal Compartment) |
| Standard | TS EN 62271-200 |
| Insulation | SF6 Gas / Air |
| Actuation | Motor / Manual |
For special voltage or current ratings, please contact our technical team. We produce custom solutions for your project.
Technical Inquiry →Contact us to request our certificates and test reports.
View Our DocumentsBrowse the models below. Available drawings can be downloaded; request unpublished documents using the model-specific email links.
For custom cell types or different current/voltage ratings not listed, please contact our technical team.
The auto-producer cell is a circuit-breaker medium-voltage switchgear configuration in the Megates ME36 product family. On this page, model ME36-14 is defined as a 36 kV Circuit-Breaker Auto-Producer Cell, and the current technical list specifies an SF6 circuit breaker with a voltage-transformer arrangement.
The listed dimensions of the ME36-14 auto-producer cell are 1750 × 1600 × 2250 mm. The final switchgear scope should be evaluated based on the single-line diagram, project voltage and current ratings, protection/metering requirements and technical specification.
Search terms such as auto-producer cell, generator cell and self-generation cell may be used for this product type. Compare the project line-up in the ME36 model list together with the other circuit-breaker, metering and connection cells.
Available manuals can be downloaded. For other documents, use the request link to email our team with the model code.
A medium-voltage switchgear line-up is selected according to the single-line diagram, rated voltage and current, short-circuit level, protection philosophy, metering requirements and the function of each panel. The ME36 family includes different modular panel functions for complete MV distribution line-ups.
When selecting medium-voltage switchgear, the rated voltage, short-circuit level, protection requirements and the arrangement of the complete line-up are important. For 12 kV, 24 kV and 36 kV projects, the ME36 model list can be used to compare incoming/outgoing, transformer protection, metering, circuit-breaker, load-break-switch, coupling and cable-connection functions. The final modular switchgear selection should be evaluated against the single-line diagram and project specification.
Please share the single-line diagram, rated voltage and current, short-circuit rating, panel quantities and functions, protection/metering requirements, motor or remote-control requirements, destination country and project schedule.
The ME36 family includes incoming/outgoing feeder panels, fused transformer protection panels, circuit-breaker feeder and protection panels, current/voltage metering panels, bus-coupler panels and cable-connection functions.
Load-break-switch incoming/outgoing, fused transformer protection, circuit-breaker switchgear, current/voltage metering, bus coupling and cable connection serve different functions. Share your 12 kV, 24 kV or 36 kV system ratings and single-line diagram to request a technical assessment for the appropriate medium-voltage switchgear line-up.
In the product list on this page, the auto-producer cell is model ME36-14, a 36 kV circuit-breaker cell with voltage transformers. The project-specific protection, metering and control scope should be confirmed according to the technical specification and single-line diagram.
Switchgear dimensions, layout and cable entries should be checked together with the kiosk arrangement. If you require both the kiosk and switchgear, specify the scope of both products in the same quotation request.
Share the required insulation and switching technology, project specification and destination country. The available model, test documents and production status should be confirmed by the technical team.