🌐 TR EN AR FR RU
Home › Products › SF6 Load Break Switch
Medium Voltage Switching

SF6 LOAD BREAK SWITCH

SF6 Load Break Switch (LBS) for 12 kV, 24 kV and 36 kV medium voltage systems, with 630 A rated current and 16 kA short-time withstand class.

12 / 24 / 36 kV 630 A 16 kA Manual / Motorized
SF6 Load Break Switch LBS for 12 24 and 36 kV medium voltage systems
Product Description

SF6 LOAD BREAK SWITCH / LBS

Megates Energy SF6 Load Break Switches are designed for switching load current in medium voltage distribution systems. Configurations are available for 12 kV, 24 kV and 36 kV applications with a 630 A rated-current configuration.

Also searched as an MV load break switch , medium voltage load break switch , SF6 load switch , LBS switch or 36 kV load break switch , the product can be integrated into incoming, outgoing and distribution cubicles.

Manual or motorized operation can be selected according to the project. For motorized applications, 24 VDC motor control can be provided when requested.

A load break switch is not the same as a circuit breaker. Where short-circuit interruption is required, the appropriate circuit breaker, fuse arrangement and protection scheme must be selected separately according to the project.

The SF6 LBS can be integrated into our metal-enclosed medium voltage switchgear for project-specific incoming and outgoing feeder applications.

Key Features
12 / 24 / 36 kV Range
Medium voltage configurations for common distribution-system voltage levels.
630 A Rated Current
Rated-current configuration for medium voltage load-switching applications.
16 kA Withstand Class
Short-time withstand class according to the selected project configuration.
Manual / Motorized Operation
Operating mechanism can be selected according to the project requirements.
24 VDC Motor Option
24 VDC motor control can be provided for motorized applications when requested.
MV Cubicle Integration
Suitable for integration into incoming, outgoing and distribution cubicle arrangements.
Technical Specifications

Technical Data

Technical Parameters — SF6 Load Break Switch
Product Type SF6 Load Break Switch (LBS)
Rated Voltage 12 kV / 24 kV / 36 kV
Rated Current 630 A
Short-Time Withstand 16 kA
Operation Manual / Motorized
Motor Control Voltage 24 VDC — on project request
Application MV incoming, outgoing and distribution cubicles
Technical Scope Confirmed according to SLD and project specification

Final operating mechanism, control voltage, interlocking arrangement and cubicle configuration are confirmed according to the project single-line diagram and technical specification.

Technical Inquiry →
Project Configuration

Technical Compliance

Project Ratings
Rated voltage, rated current and short-time withstand requirements are confirmed according to the project specification.
Interlocking
Mechanical interlocking, earthing function and operating sequence are evaluated together with the cubicle arrangement.
Motorization
Manual or motorized operation and control-voltage requirements are selected according to the project.
Documentation
Applicable technical documentation, drawings and available test documents are shared according to the offered configuration.
Our Certificates
ISO 9001:2015
Quality Management System
TSE Certificate
Turkish Standards Conformity

Contact us to request available certificates, technical documents and test documentation.

View Our Documents
Technical Documents

Request Documentation

Current technical datasheets, drawings and available test documentation can be shared according to the requested SF6 Load Break Switch and cubicle configuration.

Load Break Switch Selection Guide

MV Load Break Switch 12 / 24 / 36 kV

SF6 Load Break Switch , MV Load Break Switch , medium voltage load break switch , SF6 load switch and LBS are common technical and search terms used for this product family.

For a correct quotation, specify rated voltage, rated current, short-time withstand level, manual or motorized operation, motor control voltage, earthing-switch requirements, mechanical interlocking and the required cubicle function.

You can also review our metal-enclosed modular medium voltage switchgear and medium voltage switchgear components .

Request LBS Quote View MV Switchgear
Frequently Asked Questions

SF6 Load Break Switch FAQ

What is an SF6 Load Break Switch?

An SF6 Load Break Switch, or LBS, is used for switching load current in medium voltage distribution systems.

Which voltage levels are available?

The product configurations shown on this page cover 12 kV, 24 kV and 36 kV medium voltage applications.

What is the rated current?

The configuration shown on this page uses a 630 A rated current.

What is the short-time withstand level?

The technical configuration shown on this page uses a 16 kA short-time withstand class.

Can the LBS be motorized?

Yes. Manual or motorized operation can be selected according to project requirements. A 24 VDC motor-control option can be provided when requested.

Is a Load Break Switch the same as a circuit breaker?

No. A load break switch and a circuit breaker perform different switching and protection functions. Where short-circuit interruption is required, the appropriate circuit breaker or protection arrangement must be selected separately.

Can the LBS be integrated into MV switchgear?

Yes. The SF6 Load Break Switch can be integrated into metal-enclosed modular medium voltage switchgear for incoming, outgoing and distribution applications.

Project Consultancy

Get a Quote
for Your Project

Contact our expert team for solutions tailored to your project.

Contact Us
Megates Energy
Automated guide
Hello! This is an automated guide. Choose a topic below, or use WhatsApp to contact our team.