🌐 TR EN AR FR RU
Home›Products›METAL-CLAD WITHDRAWABLE SWITCHGEAR
Medium Voltage Switchgear

METAL-CLAD WITHDRAWABLE SWITCHGEAR

Air-insulated Metal-Clad switchgear for 12 / 24 / 36 kV primary distribution applications. Circuit-breaker, busbar, cable and low-voltage control compartments are separated by metal partitions for operational flexibility and maintenance access.

12 / 24 / 36 kVAir InsulatedWithdrawable BreakerIEC 62271-200
Product Overview

METAL-CLAD WITHDRAWABLE SWITCHGEAR

Metal-Clad switchgear is designed for primary distribution projects requiring compartmentalized construction and withdrawable switching equipment.

The withdrawable circuit breaker arrangement facilitates maintenance and equipment replacement while maintaining a clear separation between functional compartments.

Protection relays, CTs, VTs, control voltage, interlocks and cable interfaces are configured according to the single-line diagram and project specification.

Key Features
✓
Metal Compartments
Breaker, busbar, cable and control sections are separated.
✓
Withdrawable Circuit Breaker
Vacuum or suitable breaker technology is selected for the project.
✓
Primary Distribution
Designed for utility and industrial primary-distribution applications.
✓
Protection & Metering
Relay, CT and VT scope is configured according to protection philosophy.
✓
Interlocking
Mechanical and electrical interlocks are engineered for safe operation.
✓
Project Documentation
Single-line, GA and control documents can be prepared for approval.
Technical Data

Technical Parameters

METAL-CLAD WITHDRAWABLE SWITCHGEAR
Rated Voltage12 / 24 / 36 kV
InsulationAir
Circuit BreakerWithdrawable type
Rated CurrentAccording to configuration
Short-Time WithstandAccording to configuration
CompartmentsBreaker / busbar / cable / LV control
ReferenceIEC 62271-200
ClassificationLSC2B / PM / IAC only within verified type-test scope

Technical Inquiry →

Standards

Reference Standards

IEC 62271-200
Metal-enclosed AC switchgear and controlgear above 1 kV and up to 52 kV.
IEC 62271-100
Applicable to high-voltage AC circuit breakers.
IEC 62271-102
Applicable to disconnectors and earthing switches.
Project Specification
Protection, metering and control requirements are reviewed per project.

View Our Documents

Technical Documentation

Project Documentation

Technical drawings and project documents are prepared according to the selected configuration and project requirements. You can request the following documents during the quotation process.

Project Requirements

What information is required for Metal-Clad switchgear?

Provide system voltage, rated current, short-circuit level, single-line diagram, protection functions, CT/VT requirements, control voltage and cable details.

View All Products Contact Our Technical Team

Frequently Asked Questions

What does withdrawable mean?

The circuit breaker can be moved between service, test and isolated positions according to the selected design.

Are LSC2B, PM and IAC always included?

These classifications can only be stated when they are covered by the verified type-test scope of the selected product.

Can protection relays and metering be customized?

Yes. Relay functions, CTs, VTs and communication interfaces are selected according to the project specification.

Project Consultancy

Get a Quote
for Your Project

Contact our expert team for solutions tailored to your project.

Contact Us
Megates Energy
Automated guide