SF6 CIRCUIT BREAKER

SF6 medium voltage circuit breaker solutions for reliable switching and protection of 12 kV, 24 kV and 36 kV distribution systems.

12 / 24 / 36 kV 630–2000 A 16 / 25 kA IEC 62271-100
SF6 circuit breaker for 12 24 and 36 kV medium voltage systems
Product Description

SF6 CIRCUIT BREAKER

Megates Energy SF6 Circuit Breakers are designed to interrupt load currents and short-circuit currents in medium voltage distribution systems. Configurations are available for 12 kV, 24 kV and 36 kV applications.

Also searched as a medium voltage circuit breaker , MV circuit breaker , 36 kV circuit breaker or SF6 breaker , the product range covers rated currents from 630 A up to 2000 A and 16 kA / 25 kA breaking levels.

Motor-operated spring mechanisms provide fast opening and closing operation. The circuit breaker can be applied within protection and control schemes according to the project requirements.

SF6 circuit breakers can also be integrated into metal-enclosed medium voltage switchgear for incoming, outgoing, feeder protection and transformer protection applications.

Key Features
16 / 25 kA Breaking Capacity
Configurations for medium voltage short-circuit interruption requirements.
630–2000 A Rated Current
Rated-current configurations for different feeder and project requirements.
Mechanical Life
Technical data specifies a mechanical life of 10,000 operations.
Motor-Operated Spring Mechanism
Fast and reliable opening and closing actuation.
Protection & Control Integration
Can be integrated into project-specific protection and control schemes.
IEC 62271-100
Circuit-breaker design based on the applicable IEC circuit-breaker standard.
Technical Specifications

Technical Data

Technical Parameters — SF6 Circuit Breaker
Rated Voltage 12 kV / 24 kV / 36 kV
Rated Current 630 A — 2000 A
Short-Circuit Breaking 16 kA / 25 kA
Opening Time ≤ 60 ms
Mechanical Life 10,000 operations
Filling Gas SF6
Standard IEC 62271-100
Actuation Motor-Operated Spring Mechanism

Final circuit-breaker configuration, control voltage, protection scheme and operating mechanism are selected according to the project specification.

Technical Inquiry →
Compliance Standards

Our Quality Standards

IEC 62271-100
High-voltage AC circuit-breakers
IEC 62271-200
Metal-enclosed medium voltage switchgear
IEC 60694
Common specifications — high-voltage switchgear
IEC 60529
IP protection classification
Our Certificates
ISO 9001:2015
Quality Management System
TSE Certificate
Turkish Standards Compliance

Contact us to request available certificates and test documentation.

View Our Documents
Technical Documents

Request Documentation

Current technical datasheets, drawings, certificates and available test documentation can be supplied according to the requested circuit-breaker configuration.

Frequently Asked Questions

SF6 Circuit Breaker FAQ

What is an SF6 circuit breaker used for?

It is used to interrupt load currents and short-circuit currents in medium voltage distribution systems.

Which voltage levels are available?

The product range shown on this page covers 12 kV, 24 kV and 36 kV applications.

What rated currents are available?

Rated-current configurations range from 630 A up to 2000 A.

What breaking capacities are available?

The technical data on this page includes 16 kA and 25 kA short-circuit breaking levels.

What operating mechanism is used?

The listed configuration uses a motor-operated spring mechanism for circuit-breaker opening and closing operation.

Can the breaker be used in MV switchgear?

Yes. The circuit breaker can be integrated into metal-enclosed medium voltage switchgear according to the protection and switching function required by the project.

Project Consultancy

Get a Quote
for Your Project

Contact our expert team for solutions tailored to your project.

Contact Us
Megates Energy
Automated guide
Hello! This is an automated guide. Choose a topic below, or use WhatsApp to contact our team.